CML stainless steel tube fittings in SS304, SS316L and Duplex 2205

Selection, ordering & installation

How to select a CML tube fitting, build an ordering number and install double-ferrule tube fittings.

How to select a CML tube fitting

Start with the required connection function, then confirm tube system, material and pressure class.

RequirementConnectionProduct familySeries
Connect tubing to a threaded portTube O.D. to threadConnectorsMC / TMC / FC / BMC / BFC
Join equal or different tube sizesTube to tubeUnionsUN / CU / RU / BU / BRU
Change tubing direction90-degree or 45-degreeElbowsUE / URE / ME / MV / PME / PMV / FE
Create a branch or run connectionThree-way flow pathTeesUT / RUT / MBT / MRT / PMB / PMR / FBT / FRT
Create four-way distributionFour-way flow pathCrossesUC
Close or protect a tube endEnd closureCaps & PlugsTC / TP
Change size or instrument portSize or port transitionReducers & Port ConnectorsRD / BR / RE / PC / RPC
Connect to threaded endsThreaded interface transitionAdaptersMAD / FAD
Connect to weld or flange interfacesWelded or flanged interfaceWeld FittingsWAD / WDC / WDE / FGA
Add protection, flange or assembly componentsSystem accessory or componentAccessoriesVP / LFC / TN / FF / RF / NF / TMN

How to build an ordering number

Build the prefix from pressure class, product series and material, then add the basic ordering number.

Example ordering number: 3S6-MC-FT04-NM04

  1. 3Pressure class3 = 3000 psi
    6 = 6000 psi
  2. S6MaterialS4 = SS304
    S6 = SS316L
    DP = Duplex 2205
  3. MCSeriesMale connector
  4. FT04Tube O.D.1/4 in. tube
  5. NM04End connection1/4 in. NPT male
Prefix: pressure class and material codeBasic ordering number, as listed in the dimension tables
  • 3 – 3000 psi pressure prefix; 6 – 6000 psi pressure prefix.
  • Complete example: 3S6-MC-FT04-NM04. 6000 psi version: 6S6-MC-FT04-NM04.
  • Assembly-dependent items and FGA flange adapters use S6 without a pressure prefix.
  • Other materials use the same structure with their material code, for example 3S4-MC-FT04-NM04 (SS304) or 3DP-MC-FT04-NM04 (Duplex 2205). For S4 and DP, confirm the full number, including the pressure class, with us.

Pressure availability by tube O.D.

Fractional tube O.D.Metric tube O.D.Pressure class
Through 3/4 in.Through 20 mm3000 and 6000 psi
Over 3/4 through 1 in.Over 20 through 25 mm3000 psi only
Above 1 in.Above 25 mmRequires engineering approval

For multiple tube ends, the largest tube O.D. governs.

Thread types

Thread ends offered across the CML series. For how to tell them apart on a part in your hand, read how to tell NPT, BSPT, BSPP and metric threads apart.

ThreadCML codeThread angleFormSeals on
NPT (ASME B1.20.1)NM, NF60°Tapered 1:16Thread, with sealant
BSPT, R / Rc / Rp (ISO 7-1)BM, BF55°Tapered 1:16 (R, Rc)Thread, with sealant
BSPP, G (ISO 228-1)GM, GF55°ParallelWasher, O-ring or face seal
Metric (ISO 261)MT60°ParallelWasher, O-ring or face seal

Installation guide

Assembly guidance for CML double-ferrule tube fittings up to 1 in. (25 mm).

ArticlesHow to install tube fittings: step-by-step guideThread types and which threads mate

Manual installation – initial assembly

  1. Nut loosened 1/4 turn counter-clockwise from the finger-tight position123691/4 turncounter-clockwise
    01

    Loosen the nut

    Loosen the nut 1/4 turn from the finger-tight position.

  2. Half section: tubing fully inserted and bottomed against the shoulder of the fitting bodyInsert fullyTubing bottomed on the shoulderFront ferruleBack ferruleNutBody
    02

    Insert the tubing

    Fully insert the tubing until it bottoms firmly against the shoulder.

  3. Nut brought to the finger-tight position by handFinger-tightby hand, no wrench
    03

    Finger-tighten

    Bring the nut to the finger-tight position before wrench tightening.

  4. A marker draws one straight line across a flat of the nut and the matching flat of the bodyOne straight line acrossnut and body flats
    04

    Mark the nut and body

    Draw a line across one flat of the nut and the matching flat of the body. After the pull-up, the offset between the two lines shows the turns made.

  5. Body held with one wrench while the nut is tightened 1-1/4 turns with a second wrenchBody lineNut line123691-1/4 turnsNut line: 7 to 10 o’clock
    05

    Complete the pull-up

    Hold the fitting body stationary. Tighten 1-1/4 turns for standard sizes; use 3/4 turn for 1/16, 1/8 and 3/16 in. fittings and 2, 3 and 4 mm fittings.

Reinstallation

  1. Tubing marked at the back of the nut and an alignment mark across the nut and body flatsMark on tubingat the back of the nutAlignment mark acrossnut and body flats
    01

    Mark before disassembly

    Mark the tubing at the back of the nut and place an alignment mark across the nut and fitting body flats.

  2. Tubing with preset ferrules inserted until the front ferrule seats in the bodyFront ferrule seats herePreset ferrules
    02

    Seat the preset ferrules

    Insert the tubing with the preset ferrules until the front ferrule seats properly.

  3. Body held steady while the nut is rotated back to the marks12369Back to the marks
    03

    Return to the marks

    Hold the fitting body steady and tighten the nut until the alignment marks return to their original positions.

  4. Nut tightened slightly beyond the marks12369Slightly beyond
    04

    Finish slightly beyond

    Tighten the nut slightly beyond the previous pull-up position.

Presetting methods

Choose the presetting method appropriate for the tube size and installation procedure.

Turns at a glance
MethodSize rangeTightening
Manual presetting toolSizes specified by the tool1-1/4 turns (3/4 turn for small sizes)
Hydraulic presetting tool1/2 to 1 in. (12 to 25 mm)+1/2 turn
Fittings over 1 in. (25 mm)Over 1 in. (25 mm)+1/2 turn
Tube plugsAll plug sizes+1/4 turn (1/8 turn for small sizes)

Small sizes: 1/16, 1/8 and 3/16 in. fittings; 2, 3 and 4 mm fittings. Turns are counted from finger-tight.

Manual presetting tool

Applicable to the sizes specified by the tool.

  1. Secure the presetting tool; install the nut and ferrules.

  2. Insert the tubing firmly against the tool shoulder and finger-tighten the nut.

  3. Tighten 1-1/4 turns; use 3/4 turn for the small sizes listed above.

    1-1/4 turns clockwise123691-1/4 turns3/4 turn for small sizes
  4. Mark the tubing at the back of the nut before disassembly.

  5. Transfer the preset assembly to the fitting body and tighten until the mark returns to its original position.

  6. After resistance increases noticeably, tighten the nut slightly further.

Hydraulic presetting tool

Applicable to fittings from 1/2 to 1 in. (12 to 25 mm).

  1. Preset the ferrules on the tubing in accordance with the hydraulic tool instructions.

  2. Insert the preset assembly into the fitting body and finger-tighten the nut.

  3. Hold the body stationary and tighten the nut an additional 1/2 turn with a wrench.

    1/2 turn clockwise12369+1/2 turnWith a wrench
  4. For reinstallation, follow the manual reinstallation procedure.

Important: always follow the presetting tool instructions and verify that the ferrules are correctly oriented before assembly.

Special installation procedures

Fittings over 1 in. (25 mm)

1/2 turn clockwise12369+1/2 turn
  • Preset the ferrules with a hydraulic tool.
  • Insert the preset assembly and finger-tighten the nut.
  • Hold the body stationary and tighten the nut an additional 1/2 turn.
  • Use the standard reinstallation procedure for subsequent assembly.

Tube plugs

1/4 turn clockwise12369+1/4 turn1/8 turn for small sizes
  • Hold the fitting body steady.
  • Tighten the plug 1/4 turn beyond finger-tight for standard sizes, or 1/8 turn for 1/16, 1/8 and 3/16 in. fittings and 2, 3 and 4 mm fittings.
  • For reinstallation, finger-tighten, then tighten slightly with a wrench.

Port connectors

  • For the tube end, follow the installation and reinstallation procedures for tube fittings.
  • For the threaded end, follow the applicable plug installation and reinstallation procedure.

Essential safety and assembly precautions

Review these precautions before installation, inspection or maintenance.

Before assembly

  • Cleanliness

    Keep tube ends and sealing surfaces clean, undamaged and free from contamination.

  • Material match

    Tubing must be softer than the fitting. Tubing of the same material must be fully annealed.

  • Soft tubing

    Use a tube insert when assembling extremely soft plastic tubing.

  • Thread sealant

    Use a suitable sealant on tapered pipe threads and verify temperature and media compatibility.

During assembly

  • Tube insertion

    Ensure the tubing rests firmly against the shoulder before tightening.

  • Correct wrenching

    Hold the fitting or valve body stationary and turn the nut or threaded fitting as instructed.

  • Valve ends

    When assembling tube fitting ends on a valve, hold the valve body and turn the nut.

  • Threaded fittings

    When installing a threaded fitting into a valve, hold the valve body and turn the fitting body.

Pressure and inspection

  • System pressure

    Never loosen or tighten fittings while the system is pressurized.

  • Pressure rating

    The system working pressure is limited by its lowest-rated fitting, tubing or component.

  • Straight length

    Allow sufficient straight tubing length for correct installation and inspection.

  • Gap gauge

    Gap inspection gauges are intended for initial manual installation only.

Need a quote or a part that is not listed?